External tendons installed outside the existing concrete section to increase load capacity and extend service life — ideal for aging bridges with increased traffic demands.
Circumferential and vertical prestressing for concrete tanks, silos, and containment vessels — ensuring liquid-tight integrity and resisting internal pressure.
High-reliability post-tensioning systems for nuclear power plant containment structures — designed to meet strict safety and regulatory requirements for long-term performance.
Corrosion-resistant prestressing systems for offshore platforms, jetties, and marine structures — engineered for harsh environmental conditions and long service life.
Post-tensioning enables elegant, slender architectural forms — curved roofs, pedestrian bridges, and complex geometries that would not be feasible with conventional reinforcement.
External tendons with corrosion-protected strands, anchorages, and deviation saddles — designed for bridge strengthening and structural rehabilitation. Fully grouted or greased-and-sheathed options available.
Epoxy-coated · GroutedLightweight single-strand post-tensioning jacks for external tendon installation and structural strengthening. Ideal for confined spaces and incremental tensioning operations.
Portable · High precisionCustom anchorage solutions for special applications — including flush-mounted anchors, couplers, and corrosion-resistant anchorage components meeting project-specific requirements.
ASTM A416 · BS 5896| Consideration | Recommendation |
|---|---|
| External tendon routing | Use deviation saddles to achieve required force profile — avoid sharp bends to prevent strand damage |
| Corrosion protection | Select grouted or greased-and-sheathed system based on exposure conditions — critical for long-term durability |
| Anchor zone reinforcement | Ensure sufficient reinforcement to handle concentrated anchor forces — use spiral reinforcement and supplementary rebar |
| Monitoring | Install load cells and monitoring systems for long-term force verification and structural health assessment |
| Strand seating | Allow for seating losses in design calculations — typically 3–5mm for external tendons |
Liuzhou Xuanqiao Prestressing Force Machinery Co., Ltd.
Address:Block A-10-4, Hebiao Industrial Park, Yufeng District, Liuzhou City, Guangxi
Postal Code:545000
Customer service hotline:
+86 0772-2169908
+86 19101251623(Mr.Kong)
Technical Phone Number:
+86 18775155422 (Mr. Zhou)
whatsapp:+86 19101251623
Fax:+86 0772-2169908
email: info@lzxqv.com
Website:www.xqvglobal.com